Bitumen/Rubber Latex based, flexible, unary waterproofing material
https://geserparex.dumanli.net/en/water-proofing/k10-lankobitum-1k-228#sigProGalleria1ef1fa777d
Product Group : K10 LANKOBİTÜM 1K 228
Product Group : Bitumen/Rubber Latex based, flexible, unary waterproofing material
Description : Bitumen/rubber latex based, flexible, ready-to-use, unary waterproofing material
with high adherence and covering power and without any solvents.
Packaging Type : In 30 kg plastic buckets
Color : Black
Standard : Product Standard
Areas of Use : For outdoor and indoor areas, for vertical and horizontal applications in positive direction (from where the water comes from),
On newly poured concrete and damp surfaces, sustaining walls,
Foundation wall and manhole insulations,
Water and dampness-proofing of underground concrete surface,
For water insulation of metal, zinc, galvanized surfaces,
As a water and dampness barrier of parts of internal and external walls that are in contact with the soil or underground,
For affixing of thermal insulation boards.
Characteristics/Advantages : Unary,
Ready-to-use and easy application,
Applied with a brush or a spray gun,
Resistant to saline solutions and chemicals in the soil,
Durable against freeze-thaw cycle,
Acts as a bridge for capillary cracks,
Compatible to cement,
Does not include any solvents, environment-friendly.
Technical Specifications :
Binding Type : Bitumen/Rubber Latex
Color : Black
Density : 1.20±0.02 g/ml
Hard Substance : %70±2
pH : 9 - 11
Application Temperature : +5°C and +35°C
Surface Drying Time : 3 – 4 hours (at 25°C)
Drying Time before Touching : 5 – 10 hours (at 25°C)
Thorough-Dry Time : 2 – 4 days
- These figures are provided for temperatures between +23±2 ºC and for 50±5% relative humidity.
Surface Preparation:
The surfaces shall be clear of substances that may prevent adherence such as surface molding grease, dust, dirt, paint, detergent, etc. All water leakage and imperfections on the surface shall be repaired with Lanko 224 – Ertobloc or Lankorep 731 repair mortar and corners and sides should be chamfered with at least a diameter of 4 cm. If necessary, 1 kg K10 Lankobitüm 1K 228 should be diluted with 6 kg’s of water and applied as an undercoat with a roller or a brush. The application surfaces should be dry or damp-dry. No ponding should occur on the surface. Newly plastered surfaces should be cured at least 7 days before the application.
Application:
- K10 Lankobitüm 1K 228should be applied to the surface in one layer, and if necessary, in two layers with a toothed trowel (with a tooth depth of 3 mm) or flat trowel.
- After K10 Lankobitüm 1K 228is diluted with 10-20% water, it should be applied to the surface in two or three layers by a roller or a brush. Wait for 4-5 hours between layers. The required waiting time in between layers depends on the ambient temperature, surface temperature, and humidity and coating thickness.
- 10 units of K10 Lankobitüm 1K 228 and 1 unit of 52.5-Gray Cement can be mixed with 1 unit water and used for affixing of Thermal Insulation Panels with the help of a toothed trowel.
- For metal, zinc and galvanized products, 1 kg K10 Lankobitüm 1K 228 shall be diluted with 3 kg’s of water and applied as an undercoat to the surface. After the first curing of the material, the product can be applied to the surface in 1 or 2 layers.
- If another protective coating layer is to be applied on K10 Lankobitüm 1K 228, before the final layer is applied, the layer shall be sandblasted with Silica No: 1 sand, before it dries (while it is still wet). After the insulation material dries, the free sand on the surface should be wiped and cleaned and the surface shall be ready for the final coating process. Cement finish, plaster, gypsum or ceramic coatings can be applied onto the cleaned surface.
- For areas that will remain within the foundation and underground and to which this insulation product has been applied to should be protected with suitable boards and thermal insulation panels before filling.
- The product should not be applied under direct sunlight, rain and during strong winds.
Consumption: 1 kg/m²/mm thickness (application with a trowel)
0.6 - 0.8 kg/m² (two-layered applications with a brush)
2 - 3 kg/m² (for affixing of thermal insulation panels)
Storage Life:
The expiry date is 1 year from the date of production provided that it is stored in sealed (unopened) original package in a dry environment and has not been exposed to direct sunlight and frost.
Safety Precautions/Warnings:
- Use between +5 Cº and +35 Cº.
- Use protective clothing, gloves, goggles and masks during application.
- Surfaces that are not thoroughly dry should not contact water.
- Protect against freezing.
- Do not use the product under harsh weather conditions or when rain is highly possible.
- Do not use for surfaces that are exposed to negative water leakage.
- For outdoor applications, the surface shall be protected from sunlight, wind, freezing and rain for the first 24 hours.
- Wash the used tools with plenty of water after the application. The dried parts shall be cleaned with mechanical means.
- Wash with plenty of water in case of contact with skin and eyes. If it causes irritation, immediately contact a doctor.
- View Product Safety Data Sheet for more information about health and safety titles.
Hazard Warnings :
R 22 : Harmful if swallowed.
Safety Warnings :
S 2 : Keep out of the reach of children.
S 3 / 7 : Keep container tightly closed in a cool place.
S 24 / 25 : Avoid contact with skin and eyes.
S 29 : Do not empty into drains.